Zinwave Uniwave 8000 Secondary Hub Technical Specs

Unit Specifications

Power Connectivity Dual Screw Terminals AWG 12-24
Fiber Connectivity SC/APC Duplex
Other Connectivity Alarm Relay (DE-9F)
Dimensions (W / D / H) 17.48” (444mm) x 17.13” (435mm) x 1.72” (43.7mm) (1U)
Weight 15 lbs (6.8 kg)
Operating Temp (Ambient, Non-Condensing) -5°C to +45°C (23°F to 113°F)

AC Power Specifications (Input)

Min Typical Max Unit Notes
Input Voltage 90 110 / 230 264 VAC Auto-sensing Input
Input Frequency -5 50 / 60 5% Hz
Fuse -- 12 -- A Anti-surge (on PSU)

Approvals & Listings

Africa ICASA Certified
Europe CE Marked (Radio Equipment Directive 2014/53/EU, RoHS 2011/65/EC)
USA FCC Certified
Canada Industry Canada Certified
Safety IEC 60950-1, EN 60950-1, UL60950-1 (UL Listed - E486578)
Laser Safety IEC 60825-1:2007